Our new LN200 and IMAR iIMU Data Logger and power supply is now available.

 

Dimension: 19'' / 1U (482.6mm / 44.45mm) 

DATA LOGGER:
The system precisely synchronizes the incoming IMU data with GPS time and sends them over the Ethernet port. The high bandwith of communication ports easily handles up to 500Hz of IMAR IMU data and up to 400Hz of LN200 IMU data that are logged on customer-provided PC. The precisely time tagged data can be used for real-time or in post-mission GPS/INS integration. A software configuration at startup permits to switch between the IMAR iIMU-FSAS or the LN-200.

 

BUILT IN POWER SUPPLY:
Two different +24V DC inputs may be connected at the same time on the integrated power supply. This is mainly designed for airborne measurments where power supply is provided by the aircraft while the aircraft engine is runnig and by an external battery when engine is shut down. The microprocessor continuously measures the input voltage. The "helicopter" input has priority over the "battery" input, that means that as long as the input voltage on the first input is above the minimal threashold, it supplies the system's power. When the input fall under this voltage, the second input will supply the system, as long as the input voltage is above the minimal value. When first input raises above the threshold the system is again supplied by the first input.